==Detection mechanism - Brillouin Oscillations==
 
==Detection mechanism - Brillouin Oscillations==
[[File:Brillouin simple.png|200px|thumb|right]]
+
[[Image:Brillouin simple.png|200px|thumb|right]]
 
The  probe light is reflected from the sample surface to the detector, and if the sample is transparent there is also a reflection from the acoustic wave packet traveling in  the sample. This happens because the acoustic wave causes a change in  the local refractive index and so acts as a weak mirror.  These reflections interfere at the detector and as the phase of the  reflection from the acoustic wave is changing with time it leads to an oscillating  signal. These oscillations are termed Brillouin Oscillations.
 
The  probe light is reflected from the sample surface to the detector, and if the sample is transparent there is also a reflection from the acoustic wave packet traveling in  the sample. This happens because the acoustic wave causes a change in  the local refractive index and so acts as a weak mirror.  These reflections interfere at the detector and as the phase of the  reflection from the acoustic wave is changing with time it leads to an oscillating  signal. These oscillations are termed Brillouin Oscillations.
  
Line 22: Line 22:
 
the cells are grown on a transducer substrate similar to those described [[Nanoscale_Ultrasonic_Transducers|here]]. The optimization of the transducer layer is different in this case. Here we are much more concerned with optimizing the optical properties of the transducers. The goal is to reduce the amount of blue light reaching the cell and either maximize the reflected or transmitted light, depending on the experiment requirements. We still have to take care that the acoustic performance of the transducer is good and that the acoustic bandwidth is sufficient to generate waves at the Brillouin frequency.
 
the cells are grown on a transducer substrate similar to those described [[Nanoscale_Ultrasonic_Transducers|here]]. The optimization of the transducer layer is different in this case. Here we are much more concerned with optimizing the optical properties of the transducers. The goal is to reduce the amount of blue light reaching the cell and either maximize the reflected or transmitted light, depending on the experiment requirements. We still have to take care that the acoustic performance of the transducer is good and that the acoustic bandwidth is sufficient to generate waves at the Brillouin frequency.
  
 +
{|class="wikitable" align="right"
 +
|-
 +
|[[Image:Pump_Transmittance.png |thumb|150px|alt=alt text|ASOPS pump probe instrument]][[Image:Transmittance_Probe.png |thumb|150px|alt=alt text|ASOPS pump probe instrument]]
 +
|-
 +
|[[Image:Transmitance_sensitivity.png |thumb|150px|alt=alt text|ASOPS pump probe instrument]][[Image:Resonance_Freqs.png |thumb|150px|alt=alt text|ASOPS pump probe instrument]]
 +
|}
 +
<br style="clear:both" />
 
==Example results==
 
==Example results==
  

Revision as of 12:20, 17 October 2013

Motivation

Instrument

description of the ASOPS pump probe system and figure.

alt text
ASOPS pump probe instrument


Detection mechanism - Brillouin Oscillations

Brillouin simple.png

The probe light is reflected from the sample surface to the detector, and if the sample is transparent there is also a reflection from the acoustic wave packet traveling in the sample. This happens because the acoustic wave causes a change in the local refractive index and so acts as a weak mirror. These reflections interfere at the detector and as the phase of the reflection from the acoustic wave is changing with time it leads to an oscillating signal. These oscillations are termed Brillouin Oscillations.

The frequency F of the oscillation is given by the simple equation: F = 2*Va*n/λ

So if we can measure this signal we can measure the acoustic velocity Va, as long as we know the laser wavelength λ and the refractive index n.


Substrate Design

the cells are grown on a transducer substrate similar to those described here. The optimization of the transducer layer is different in this case. Here we are much more concerned with optimizing the optical properties of the transducers. The goal is to reduce the amount of blue light reaching the cell and either maximize the reflected or transmitted light, depending on the experiment requirements. We still have to take care that the acoustic performance of the transducer is good and that the acoustic bandwidth is sufficient to generate waves at the Brillouin frequency.